W1209 Mini thermostat Temperature controller is low-cost 12V Temperature controller with 7-segment display and 3 switch keypad for setting temperature and other parameters. The module features an NTC thermistor temperature sensing and has an accuracy of 0.1 C. The XH W1209 digital temperature controller Module W/ Display and NTC Waterproof Temperature Sensor is an incredibly low cost yet highly functional thermostat controller. With this module, you can intelligently control power to most types of electrical devices based on the temperature sensed by the included high accuracy NTC temperature sensor. We can display the current temperature in degrees Centigrade via its 3 digits seven-segment display and the current relay state by an onboard LED. The thermostat will display the current temperature in °C by default. When in any other mode making no input for approximately 5 seconds will cause the thermostat to return to this default display. To set the trigger temperature press the button marked ‘SET’. The seven-segment display will flash. You can now set a trigger temperature (in °C) using the ‘+’ and ‘-‘ buttons in 0.1° increments. If we didn’t press any buttons for approximately 2 seconds the trigger temperature will be store and the display will return back to the current temperature. To set any parameter first long press the ‘SET’ button for at least 5 seconds. The seven-segment display should now display ‘P0’. This represents parameter P0. Pressing the ‘+’ or ‘-‘ buttons will cycle through the various parameters (P0 to P6). Pressing the ‘SET’ button whilst any of these parameters are displayed will allow you to change the value for that parameter using the ‘+’ and ‘-‘ buttons. When finished setting a parameter press the set button to exit that option. If no buttons are pressed for approximately 5 seconds the thermostat will exit the parameter options and will return back to the default temperature display. The parameter P0 has two settings, C and H. When setting to C (default) the relay will energize when the temperature is reached. Use this setting if connecting to an air-conditioning system. When set to H the relay will de-energize when the temperature is reached. Use this setting if controlling a heating device. This sets how much change in temperature must occur before the relay will change state. For example, if set to the default 2oC and the trigger temperature has been set to 25oC, it will not de-energize until the temperature falls back below 23oC. Setting this hysteresis helps stop the thermostat from continually triggering when the temperature drifts around the trip temperature. This parameter limits the maximum trigger temperature that can be set. It is useful as a safety to stop an excessively high trigger temperature from accidentally being set by the user. This parameter limits the minimum trigger temperature that can be set. It is useful as a safety to stop an excessively low trigger temperature from accidentally being set by the user. Should you find there is a difference between the displayed temperature and the actual temperature; (for instance, if the temperature probe is on a long run of cable) you can make minor corrections to the temperature reading with this parameter. To reach trigger temperature this parameter allows for delaying switching of the relay. The parameter can be set in one-minute increments up to a maximum of 10 minutes. Setting a value for this parameter will cause the relay to switch off when the temperature reaches this setting. The seven-segment display will also show ‘—‘ to indicate an alarm condition. The relay will not re-energize until the temperature falls below this value. The default setting is OFF. Note: The 12v relay module may differ in the manufacturer’s name & type from the image. Long press the “SET” button to activate the menu. (SET THE VALUES AS MENTIONED IN BRACKET)Displaying the current temperature
Setting the trigger temperature
Setting the parameters
Setting the cooling or heating parameter P0
Setting the hysteresis parameter P1
Setting the upper limit of the thermostat parameter P2
Setting the lower limit of the thermostat parameter P3
Setting temperature offset correction parameter P4
Setting the trigger delay parameter P5
Setting the high-temperature alarm parameter P6
Settings Chart
Code Description Range Default Value
P0 Heat C/H (C)
P1 Backlash Set 0.1-15 (2)
P2 Upper Limit 110 (110)
P3 Lower Limit -39 (-39)
P4 Correction -7.0 ~ (0)
P5 Delay Start Time 0-10 mins (0)
P6 High-Temperature Alarm 0-110 (OFF)
Long pressing “+/-” will reset all values to their default
Shipping Policies
- To ensure that your order reaches you in the fastest time and in good condition, we only ship through reputed courier agencies.
- While we shall strive to ship all items in your order together, this may not always be possible due to product characteristics, or availability. However, we will inform you before doing it.
- If you believe that the product is not in good condition, or if the packaging is tampered with or damaged, before accepting delivery of the goods, please refuse to take delivery of the package, and call our Customer Care 1800 266 6123 / 020 68197600 or Contact us, mentioning your order reference number. We shall make our best efforts to ensure that a replacement delivery is made to you at the earliest.
- You may track the shipping status of your order on our website, by clicking at Track your Order section.
- Please note all items (including gifts) will be shipped with an invoice mentioning the price, as per Indian Tax Regulations.
Reviews
There are no reviews yet.